Search

LE COSINUS search tool allows you to search quickly and accurately, to find a product datasheet. For a specific product, please contact us.

If you have the reference of the product, enter it below

Alternatively you can search for a product by criteria

Type of product

Sub-category

Number of Phases

Power/Value

Voltage(s)/Current

Indice IP

Result (249 product(s))

Transformers

  • Power/Value
    Reference
    Protection
    Wording
  • 40 VA
    1M400-TN-X089
    IP20
    Transformers Single-Phase 40 VA 230.400V ±15V / 24V - IP20
    • 1M400-TN-X089

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        75 x 75 x 83

      • Fixings: X x Y x ∅ (mm)

        56 x (46.4 - 55) x 4.7

      • Weight

        1.22

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 40 VA
    1M400-TN-K342
    IP00
    Transformers Single-Phase 40 VA 230.400V ±15V / 230V - IP00
    • 1M400-TN-K342

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        75 x 75 x 83

      • Fixings: X x Y x ∅ (mm)

        56 x (46.4 - 55) x 4.7

      • Weight

        1.2

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 40 VA
    1M400-TN-G506
    IP00
    Transformers Single-Phase 40 VA 230.400V / 24V - IP00
    • 1M400-TN-G506

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        75 x 75 x 83

      • Fixings: X x Y x ∅ (mm)

        56 x (46.4 - 55) x 4.7

      • Weight

        1.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 63 VA
    1M630-TN-X090
    IP20
    Transformers Single-Phase 63 VA 230.400V ±15V / 24V - IP20
    • 1M630-TN-X090

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        84 x 80 x 89

      • Fixings: X x Y x ∅ (mm)

        64 x (42.8 - 53.4) x 4.7

      • Weight

        1.2

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 63 VA
    1M630-TN-K343
    IP00
    Transformers Single-Phase 63 VA 230.400V ±15V / 230V - IP00
    • 1M630-TN-K343

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 80 x 89

      • Fixings: X x Y x ∅ (mm)

        64 x (42.8 - 53.4) x 4.7

      • Weight

        2

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 63 VA
    1M630-TN-W136
    IP00
    Transformers Single-Phase 63 VA 230.400V / 24.48V PP - IP00
    • 1M630-TN-W136

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 80 x 89

      • Fixings: X x Y x ∅ (mm)

        64 x (42.8 - 53.4) x 4.7

      • Weight

        1.7

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 63 VA
    1M630-TN-G512
    IP00
    Transformers Single-Phase 63 VA 230.400V / 24V - IP00
    • 1M630-TN-G512

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 80 x 89

      • Fixings: X x Y x ∅ (mm)

        64 x (42.8 - 53.4) x 4.7

      • Weight

        1.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 100 VA
    1M101-TN-R893
    IP00
    Transformers Single-Phase 100 VA 230.400V / 115.230V PP - IP00
    • 1M101-TN-R893

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 100 VA
    1M101-TN-V879
    IP00
    Transformers Single-Phase 100 VA 230.400V / 24.48V PP - IP00
    • 1M101-TN-V879

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 100 VA
    1T101-TN-G235
    IP00
    Transformers Three-Phase 100 VA 400V / 230V - IP00
    • 1T101-TN-G235

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A /

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 100 VA
    1M101-TN-W789
    IP20
    Transformers Single-Phase 100 VA 230.400V ±15V / 24V - IP20
    • 1M101-TN-W789

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 100 VA
    1M101-TN-G518
    IP00
    Transformers Single-Phase 100 VA 230.400V / 24V - IP00
    • 1M101-TN-G518

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 100 VA
    1M101-TN-K344
    IP00
    Transformers Single-Phase 100 VA 230.400V ±15V / 230V - IP00
    • 1M101-TN-K344

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2.1

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 160 VA
    1M161-TN-T219
    IP00
    Transformers Single-Phase 160 VA 230.400V / 115.230V PP - IP00
    • 1M161-TN-T219

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        3.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 160 VA
    1M161-TN-R757
    IP00
    Transformers Single-Phase 160 VA 230.400V / 24.48V PP - IP00
    • 1M161-TN-R757

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        4

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 160 VA
    1M161-TN-X091
    IP20
    Transformers Single-Phase 160 VA 230.400V ±15V / 24V - IP20
    • 1M161-TN-X091

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        3.3

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 160 VA
    1T161-TN-V881
    IP00
    Transformers Three-Phase 160 VA 400V / 230V - IP00
    • 1T161-TN-V881

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        Dyn11

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 160 VA
    1M161-TN-G527
    IP00
    Transformers Single-Phase 160 VA 230.400V / 24V - IP00
    • 1M161-TN-G527

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        3.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 160 VA
    1M161-AB-P465
    IP21
    Transformers Single-Phase 160 VA 230.400V ±15V / 230V - IP21
    • 1M161-AB-P465

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        250 x 170 x 210

      • Fixings: X x Y x ∅ (mm)

        225 x (120 - 75.9) x 7

      • Weight

        6.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 160 VA
    1M161-TN-K345
    IP00
    Transformers Single-Phase 160 VA 230.400V ±15V / 230V - IP00
    • 1M161-TN-K345

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        3.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 250 VA
    1M251-TN-X092
    IP20
    Transformers Single-Phase 250 VA 230.400V ±15V / 24V - IP20
    • 1M251-TN-X092

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        4.41

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 250 VA
    1M251-TN-K346
    IP00
    Transformers Single-Phase 250 VA 230.400V ±15V / 230V - IP00
    • 1M251-TN-K346

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 250 VA
    1T251-TN-G237
    IP00
    Transformers Three-Phase 250 VA 400V / 230V - IP00
    • 1T251-TN-G237

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        150 x 105 x 149

      • Fixings: X x Y x ∅ (mm)

        125 x (72 - 85) x 6.5

      • Weight

        4.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 250 VA
    1M251-TN-S296
    IP00
    Transformers Single-Phase 250 VA 230.400V / 24.48V PP - IP00
    • 1M251-TN-S296

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 250 VA
    1M251-AB-S343
    IP21
    Transformers Single-Phase 250 VA 230.400V ±15V / 230V - IP21
    • 1M251-AB-S343

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        250 x 170 x 210

      • Fixings: X x Y x ∅ (mm)

        225 x (120 - 88.9) x 7

      • Weight

        8

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 250 VA
    1M251-TN-G530
    IP00
    Transformers Single-Phase 250 VA 230.400V / 24V - IP00
    • 1M251-TN-G530

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 250 VA
    1M251-TN-X094
    IP20
    Transformers Single-Phase 250 VA 230.400V ±15V / 230V - IP20
    • 1M251-TN-X094

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        4.41

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 250 VA
    1M251-TN-R827
    IP00
    Transformers Single-Phase 250 VA 230.400V / 115.230V PP - IP00
    • 1M251-TN-R827

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-K347
    IP00
    Transformers Single-Phase 400 VA 230.400V ±15V / 230V - IP00
    • 1M401-TN-K347

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        6.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-S046
    IP00
    Transformers Single-Phase 400 VA 230.400V / 115.230V PP - IP00
    • 1M401-TN-S046

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        7

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 400 VA
    1T401-TN-G238
    IP00
    Transformers Three-Phase 400 VA 400V / 230V - IP00
    • 1T401-TN-G238

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        180 x 95 x 177

      • Fixings: X x Y x ∅ (mm)

        145 x (51 - 65) x 7

      • Weight

        6.5

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 1A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-X095
    IP20
    Transformers Single-Phase 400 VA 230.400V ±15V / 24V - IP20
    • 1M401-TN-X095

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        6.07

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 400 VA
    1M401-AB-T895
    IP21
    Transformers Single-Phase 400 VA 230.400V ±15V / 230V - IP21
    • 1M401-AB-T895

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        250 x 170 x 210

      • Fixings: X x Y x ∅ (mm)

        225 x (120 - 76) x 7

      • Weight

        9

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-X096
    IP20
    Transformers Single-Phase 400 VA 230.400V ±15V / 230V - IP20
    • 1M401-TN-X096

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        6.07

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A /

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-T203
    IP00
    Transformers Single-Phase 400 VA 230.400V / 24.48V PP - IP00
    • 1M401-TN-T203

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        7

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 400 VA
    1M401-TN-G533
    IP00
    Transformers Single-Phase 400 VA 230.400V / 24V - IP00
    • 1M401-TN-G533

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        6.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1M631-TN-S035
    IP00
    Transformers Single-Phase 630 VA 230.400V / 115.230V PP - IP00
    • 1M631-TN-S035

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        11

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 6A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1M631-TN-K348
    IP00
    Transformers Single-Phase 630 VA 230.400V ±15V / 230V - IP00
    • 1M631-TN-K348

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        10

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 630 VA
    1M631-AB-S223
    IP21
    Transformers Single-Phase 630 VA 230.400V ±15V / 230V - IP21
    • 1M631-AB-S223

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        122 x (300 - 103) x 10

      • Weight

        14

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 630 VA
    1T631-TN-G239
    IP00
    Transformers Three-Phase 630 VA 400V / 230V - IP00
    • 1T631-TN-G239

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        180 x 105 x 177

      • Fixings: X x Y x ∅ (mm)

        145 x (61 - 75) x 7

      • Weight

        8.2

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1M631-TN-R823
    IP00
    Transformers Single-Phase 630 VA 230.400V / 24.48V PP - IP00
    • 1M631-TN-R823

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        10

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 5A / DJ C - 25A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1M631-TN-G536
    IP00
    Transformers Single-Phase 630 VA 230.400V / 24V - IP00
    • 1M631-TN-G536

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        9.5

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 25A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1T631-TN-N112
    IP00
    Transformers Three-Phase 630 VA 400V / 400V - IP00
    • 1T631-TN-N112

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        180 x 105 x 177

      • Fixings: X x Y x ∅ (mm)

        145 x (61 - 75) x 7

      • Weight

        8

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1M102-TN-K349
    IP00
    Transformers Single-Phase 1 KVA 230.400V ±15V / 230V - IP00
    • 1M102-TN-K349

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        13

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 1 KVA
    1M102-TN-G539
    IP00
    Transformers Single-Phase 1 KVA 230.400V / 24V - IP00
    • 1M102-TN-G539

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        13

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 40A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1T102-TN-G240
    IP00
    Transformers Three-Phase 1 KVA 400V / 230V - IP00
    • 1T102-TN-G240

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        180 x 125 x 177

      • Fixings: X x Y x ∅ (mm)

        145 x (81 - 95) x 7

      • Weight

        12

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1M102-TN-R826
    IP00
    Transformers Single-Phase 1 KVA 230.400V / 115.230V PP - IP00
    • 1M102-TN-R826

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        14

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1M102-TN-S050
    IP00
    Transformers Single-Phase 1 KVA 230.400V / 24.48V PP - IP00
    • 1M102-TN-S050

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        14

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 40A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1T102-AB-P664
    IP21
    Transformers Three-Phase 1 KVA 400V / 400V - IP21
    • 1T102-AB-P664

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        145 x (300 - 95) x 10

      • Weight

        15

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1T102-TN-J108
    IP00
    Transformers Three-Phase 1 KVA 400V / 400V - IP00
    • 1T102-TN-J108

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        180 x 125 x 177

      • Fixings: X x Y x ∅ (mm)

        145 x (81 - 95) x 7

      • Weight

        11

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1M102-AB-P334
    IP21
    Transformers Single-Phase 1 KVA 230.400V ±15V / 230V - IP21
    • 1M102-AB-P334

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        122 x (300 - 128) x 10

      • Weight

        17

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 1 KVA
    1T102-AB-G271
    IP21
    Transformers Three-Phase 1 KVA 400V / 230V - IP21
    • 1T102-AB-G271

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        145 x (300 - 95) x 10

      • Weight

        15

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    1T102-AB-P572
    IP21
    Transformers Three-Phase 1 KVA 230V / 400V - IP21
    • 1T102-AB-P572

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        145 x (300 - 95) x 10

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 40A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1T162-AB-G273
    IP21
    Transformers Three-Phase 1.6 KVA 400V / 230V - IP21
    • 1T162-AB-G273

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 94) x 10

      • Weight

        25

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1M162-TN-G545
    IP00
    Transformers Single-Phase 1.6 KVA 230.400V / 24V - IP00
    • 1M162-TN-G545

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 166 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (120 - 133) x 9

      • Weight

        19

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 63A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1M162-TN-V880
    IP00
    Transformers Single-Phase 1.6 KVA 230.400V / 115.230V PP - IP00
    • 1M162-TN-V880

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 166 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (120 - 133) x 9

      • Weight

        19

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1M162-TN-K350
    IP00
    Transformers Single-Phase 1.6 KVA 230.400V ±15V / 230V - IP00
    • 1M162-TN-K350

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 166 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (120 - 133) x 9

      • Weight

        18.6

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 1.6 KVA
    1T162-AB-L477
    IP21
    Transformers Three-Phase 1.6 KVA 230V / 400V - IP21
    • 1T162-AB-L477

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 94) x 10

      • Weight

        23.92

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1T162-AB-G805
    IP21
    Transformers Three-Phase 1.6 KVA 400V / 400V - IP21
    • 1T162-AB-G805

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        200 x (300 - 94) x 10

      • Weight

        20

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1T162-TN-L045
    IP00
    Transformers Three-Phase 1.6 KVA 230V / 400V - IP00
    • 1T162-TN-L045

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1T162-TN-J031
    IP00
    Transformers Three-Phase 1.6 KVA 400V / 400V - IP00
    • 1T162-TN-J031

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Weight

        17

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 5A / DJ C - 3A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1T162-TN-G242
    IP00
    Transformers Three-Phase 1.6 KVA 400V / 230V - IP00
    • 1T162-TN-G242

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Weight

        17

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    1M162-AB-T314
    IP21
    Transformers Single-Phase 1.6 KVA 230.400V ±15V / 230V - IP21
    • 1M162-AB-T314

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        150 x (300 - 133) x 10

      • Weight

        24

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-AB-N822
    IP21
    Transformers Three-Phase 2 KVA 230V / 400V - IP21
    • 1T202-AB-N822

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 94) x 10

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1B202-AB-U010
    IP21
    Transformers Three-Phase to Single-Phase 2 KVA 400V / 230V MONO - IP21
    • 1B202-AB-U010

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        T-M

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        250 x (340 - 104) x 10

      • Weight

        37

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-AB-G274
    IP21
    Transformers Three-Phase 2 KVA 400V / 230V - IP21
    • 1T202-AB-G274

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 94) x 10

      • Weight

        25

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 6A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-TN-N903
    IP00
    Transformers Three-Phase 2 KVA 230V / 400V - IP00
    • 1T202-TN-N903

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Weight

        17

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-TN-S034
    IP00
    Transformers Three-Phase 2 KVA 400V / 400V - IP00
    • 1T202-TN-S034

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Weight

        18

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1M202-TN-S191
    IP00
    Transformers Single-Phase 2 KVA 230.400V / 115.230V PP - IP00
    • 1M202-TN-S191

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 190 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (106 - 166) x 9

      • Weight

        30

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 20A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1M202-AB-R197
    IP21
    Transformers Single-Phase 2 KVA 230.400V ±15V / 230V - IP21
    • 1M202-AB-R197

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        200 x (300 - 166) x 10

      • Weight

        24

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Electrostatic Screen

        Yes

  • 2 KVA
    1B202-TN-T816
    IP00
    Transformers Three-Phase to Single-Phase 2 KVA 400V / 230V MONO - IP00
    • 1B202-TN-T816

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        T-M

      • Dimensions (L x l x H)

        300 x 148 x 297

      • Fixings: X x Y x ∅ (mm)

        250 x (84 - 104) x 10

      • Weight

        27

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-AB-K026
    IP21
    Transformers Three-Phase 2 KVA 400V / 400V - IP21
    • 1T202-AB-K026

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 94) x 10

      • Weight

        25

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1T202-TN-G243
    IP00
    Transformers Three-Phase 2 KVA 400V / 230V - IP00
    • 1T202-TN-G243

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 126 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (74 - 94) x 10

      • Weight

        18

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 6A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1M202-TN-G548
    IP00
    Transformers Single-Phase 2 KVA 230.400V / 24V - IP00
    • 1M202-TN-G548

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 170 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (130 - 143) x 9

      • Weight

        23

      • Standard

        IEC 61558-2-6

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 80A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    1M202-TN-K351
    IP00
    Transformers Single-Phase 2 KVA 230.400V ±15V / 230V - IP00
    • 1M202-TN-K351

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 170 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (130 - 143) x 9

      • Weight

        23

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 2.5 KVA
    1T252-AB-P132
    IP21
    Transformers Three-Phase 2.5 KVA 400V / 400V - IP21
    • 1T252-AB-P132

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 104) x 10

      • Weight

        29

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2.5 KVA
    1B252-TN-T538
    IP00
    Transformers Three-Phase to Single-Phase 2.5 KVA 400V / 230V MONO - IP00
    • 1B252-TN-T538

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        T-M

      • Dimensions (L x l x H)

        300 x 148 x 297

      • Fixings: X x Y x ∅ (mm)

        250 x (84 - 104) x 10

      • Weight

        28

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2.5 KVA
    1B252-AB-R525
    IP21
    Transformers Three-Phase to Single-Phase 2.5 KVA 400V / 230V MONO - IP21
    • 1B252-AB-R525

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Coupling

        T-M

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        250 x (340 - 104) x 10

      • Weight

        35

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2.5 KVA
    1M252-TN-K352
    IP00
    Transformers Single-Phase 2.5 KVA 230.400V ±15V / 230V - IP00
    • 1M252-TN-K352

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 190 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (106 - 166) x 9

      • Weight

        31

      • Standard

        IEC 61558-2-4

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        2500V / 4000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 2.5 KVA
    1T252-TN-G109
    IP00
    Transformers Three-Phase 2.5 KVA 400V / 230V - IP00
    • 1T252-TN-G109

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Coupling

        Dyn11

      • Dimensions (L x l x H)

        240 x 136 x 234

      • Fixings: X x Y x ∅ (mm)

        200 x (84 - 104) x 10