{"id":96616,"date":"2026-11-10T09:00:00","date_gmt":"2026-11-10T08:00:00","guid":{"rendered":"https:\/\/www.lecosinus.fr\/?p=96616"},"modified":"2026-10-30T12:37:38","modified_gmt":"2026-10-30T11:37:38","slug":"magnetic-steel-sheets-role-in-transformer-efficiency","status":"publish","type":"post","link":"https:\/\/www.lecosinus.fr\/en\/toles-magnetiques-leur-role-dans-le-rendement-des-transformateurs\/","title":{"rendered":"Magnetic Sheets: Their Role in Transformer Efficiency"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers.png\" alt=\"Sch\u00e9ma de t\u00f4les magn\u00e9tiques fines et isol\u00e9es limitant les courants de Foucault pour am\u00e9liorer le rendement des transformateurs\" class=\"wp-image-96617\" srcset=\"https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers.png 1200w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-300x300.png 300w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-1024x1024.png 1024w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-150x150.png 150w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-768x768.png 768w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-12x12.png 12w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-600x600.png 600w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/10\/Magnetic-Steel-Sheets-and-High-Efficiency-Transformers-100x100.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In an industrial transformer operating at 50 or 60 Hz, the magnetic circuit generally consists of a stack of magnetic laminations. These thin, individually insulated laminations limit eddy currents. Their quality and assembly have a direct impact on the transformer\u2019s efficiency, particularly on iron losses.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overall efficiency also depends on the windings, the load factor, the temperature, and the operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Role of the Magnetic Circuit <\/h2>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">In an <a href=\"https:\/\/www.lecosinus.fr\/en\/transformers\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/transformers\/\u201d\" target=\"_self\">electrical transformer<\/a>, the alternating current flowing through the primary winding creates a varying magnetic flux. The core channels this flux to the secondary winding, across which a voltage is induced.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a solid steel core, this varying magnetic flux would induce significant eddy currents, which cause energy losses and heating. To limit this phenomenon, the magnetic circuit is divided into thin laminations coated with an insulating layer, which are then stacked to form the laminated core.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Causes of Iron Losses<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As soon as power is applied to the transformer, the magnetic circuit dissipates a portion of the energy it receives. These losses, known as iron losses, occur even when the transformer is operating at no load. They are primarily caused by hysteresis and eddy currents.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Hysteresis losses <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The magnetic flux varies periodically under the influence of the alternating current. The core material then undergoes successive cycles of magnetization and demagnetization, which result in energy dissipation in the form of heat. These losses depend, in particular, on the material\u2019s properties, the frequency, and the level of magnetic induction. The choice of magnetic steel must therefore be tailored to the transformer\u2019s operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Eddy-current losses<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The varying magnetic flux induces eddy currents in the core. The magnitude of the associated losses depends, in particular, on the frequency of the magnetic flux, the magnetic induction, and the thickness of the laminations. To minimize these losses, the core is made up of thin laminations that are electrically insulated from one another, which reduces the flow of these currents and the resulting heat generation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Relationship Between Magnetic Sheets and Efficiency<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A suitable magnetic core can reduce some of the no-load losses. This reduction is particularly significant when a transformer remains energized for long periods, even when the connected load is operating at low capacity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Iron losses must be distinguished from Joule losses in the windings. The latter increase with the square of the current supplied to the load. A high-efficiency transformer therefore relies on a coherent system comprising the magnetic circuit, windings, sizing, cooling, and load factor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The quality of magnetic sheets and their assembly<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">The characteristics of magnetic sheets that affect performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Several characteristics influence the performance of magnetic sheets, including their specific losses\u2014given for a reference frequency and induction\u2014their thickness, their silicon content, and their magnetic permeability. Silicon increases the electrical resistivity of the steel, which helps limit eddy currents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Grain-oriented steel sheets are particularly well-suited when the magnetic flux follows a preferred direction. The choice of material must also take into account the operating frequency of the <a href=\"https:\/\/www.lecosinus.fr\/en\/transformers\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/transformers\/\u201d\" target=\"_self\">transformer<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The cutting and assembly of the core also play an important role. A damaged insulating coating, poorly fitted joints, or improper clamping can increase losses and vibrations. The core\u2019s performance therefore depends on the properties of the steel sheets and on the precision of their manufacture and assembly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Effects on Temperature and Noise <\/h2>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Reducing iron losses limits core heating. The transformer\u2019s temperature also depends on losses in the windings, ventilation, ambient temperature, and load factor. For more information on this topic, see our article on <a href=\"https:\/\/www.lecosinus.fr\/en\/understanding-transformer-temperature-rise-and-insulation-classes\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/understanding-transformer-temperature-rise-and-insulation-classes\/\u201d\" target=\"_self\">\u201cHeating and Insulation Classes of Transformers<\/a>.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Metal sheets also deform very slightly under the effect of alternating current. This phenomenon, called magnetostriction, contributes to the transformer\u2019s normal humming sound. The tightness of the core, the fasteners, and the power supply conditions can also affect this noise. See our article on <a href=\"https:\/\/www.lecosinus.fr\/en\/why-is-my-transformer-making-noise\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/why-is-my-transformer-making-noise\/\u201d\" target=\"_self\">transformer noise<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Selecting a High-Efficiency Transformer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To compare two transformers, you must examine their no-load and load losses and then relate them to the actual operating conditions of the system. A stated efficiency rating without an indication of the load factor is not sufficient to estimate energy losses over time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Choosing the right power rating is also essential. An incorrectly sized transformer may operate far from its intended load rating or overheat. Our guide explains <a href=\"https:\/\/www.lecosinus.fr\/en\/how-to-calculate-the-required-power-for-a-transformer\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/how-to-calculate-the-required-power-for-a-transformer\/\u201d\" target=\"_self\">how to calculate the required power of a transformer<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, the frequency, operating mode, ambient temperature, and presence of harmonics must be reported to the manufacturer. This information allows the magnetic circuit and windings to be sized according to actual operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A design tailored to the project<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le Cosinus con\u00e7oit des transformateurs standards et sur mesure. Les tensions, la puissance, les contraintes thermiques et les conditions d&rsquo;alimentation sont \u00e9tudi\u00e9es selon l&rsquo;installation. <\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">To discuss your needs and get a quote, <a href=\"https:\/\/www.lecosinus.fr\/en\/quote-request\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/quote-request\/\u201d\" target=\"_self\">share your project with the Cosinus team<\/a>.<\/p>\n\n\n\t<div class=\"lc-cta-hubspot\" data-no-translation>\n\t\t<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-221849051559\"\n\t\t\tstyle=\"max-width:100%; max-height:100%; width:700px; height:237.890625px\"\n\t\t\tdata-hubspot-wrapper-cta-id=\"221849051559\">\n\t\t\t<a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLJqHZbT6vIi5d4%2B%2F1Vg1DMjk1zXL9PX2KXgGwu1MmSL%2B3yG%2FbPMXKk3tEk1y%2Ba8dNt%2F%2Ft3zKoBwy9RUiYNaw96%2BhiL7o2JUQq%2FnN55ifPq0bMP4%2F7rxCzGmSr4vR3CtnvcPWXFzeOZhE1k54o1lyhUEHKMYczmJ0Ex6vMkoADSpD4Ax4lVD3GWCescf9Q%3D%3D&#038;webInteractiveContentId=221849051559&#038;portalId=48243687\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n\t\t\t\t<img alt=\"Request for a quote Enter your product reference number or specify the features of the product you are looking for\"\n\t\t\t\t\tloading=\"lazy\"\n\t\t\t\t\tsrc=\"https:\/\/no-cache.hubspot.com\/cta\/default\/48243687\/interactive-221849051559.png\"\n\t\t\t\t\tstyle=\"height: 100%; width: 100%; object-fit: fill\"\n\t\t\t\t\tonerror=\"this.style.display='none'\" \/>\n\t\t\t<\/a>\n\t\t<\/div>\n\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Dans un transformateur industriel fonctionnant \u00e0 50 ou 60 Hz, le circuit magn\u00e9tique est g\u00e9n\u00e9ralement constitu\u00e9 d&rsquo;un empilement de t\u00f4les magn\u00e9tiques. Fines et isol\u00e9es entre elles, ces t\u00f4les limitent les courants de Foucault. Leur qualit\u00e9 et leur assemblage ont un impact direct sur le rendement du transformateur, notamment sur les pertes fer. Le rendement global [&hellip;]<\/p>\n","protected":false},"author":4387,"featured_media":96617,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-96616","post","type-post","status-publish","format-standard","has-post-thumbnail","category-qualite"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96616","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/users\/4387"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/comments?post=96616"}],"version-history":[{"count":12,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96616\/revisions"}],"predecessor-version":[{"id":96655,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96616\/revisions\/96655"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/media\/96617"}],"wp:attachment":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/media?parent=96616"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/categories?post=96616"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/tags?post=96616"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}