{"id":96743,"date":"2026-11-24T09:00:00","date_gmt":"2026-11-24T08:00:00","guid":{"rendered":"https:\/\/www.lecosinus.fr\/?p=96743"},"modified":"2026-11-24T14:53:41","modified_gmt":"2026-11-24T13:53:41","slug":"what-are-the-efficiency-requirements-for-transformers","status":"publish","type":"post","link":"https:\/\/www.lecosinus.fr\/en\/quelles-obligations-pour-le-rendement-des-transformateurs\/","title":{"rendered":"What are the performance requirements for transformers?"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers.png\" alt=\"llustration Ecodesign pr\u00e9sentant les obligations r\u00e9glementaires li\u00e9es au rendement \u00e9nerg\u00e9tique des transformateurs \u00e9lectriques\" class=\"wp-image-96744\" srcset=\"https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers.png 1200w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-300x300.png 300w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-1024x1024.png 1024w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-150x150.png 150w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-768x768.png 768w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-12x12.png 12w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-600x600.png 600w, https:\/\/www.lecosinus.fr\/wp-content\/uploads\/2026\/11\/What-are-the-performance-requirements-for-transformers-100x100.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">There is no single mandatory efficiency standard that applies to all transformers. In the European Union, the requirements depend on power rating, voltage, technology, and intended use. Depending on the category, manufacturers must either report losses or comply with maximum loss limits and a minimum energy efficiency level. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What regulations govern transformer efficiency?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">The applicable requirements are set forth in <a href=\"https:\/\/eur-lex.europa.eu\/FR\/legal-content\/summary\/ecodesign-requirements-power-transformers.html\" data-type=\"link\" data-id=\"https:\/\/eur-lex.europa.eu\/FR\/legal-content\/summary\/ecodesign-requirements-power-transformers.html\" target=\"_self\">Regulation (EU) No. 548\/2014<\/a>, as amended by Regulation (EU) 2019\/11783. This regulation is often referred to as the Ecodesign Regulation for transformers. It primarily applies to transformers with a capacity of at least 1 kVA used in 50-Hz power grids or in industrial applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Certain transformers designed for measurement, welding, or specific applications may be subject to exclusions. The list of such transformers and the applicable conditions must be verified in the official text. The European Commission states that the current regulation remains in effect following its review.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How do you measure a transformer's efficiency and losses?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">These requirements are not expressed as a single efficiency rating. Compliance is based primarily on no-load losses, denoted as P0, and load losses, denoted as Pk. No-load losses occur as soon as power is supplied to the transformer, even if no load is connected. Load losses increase with the current delivered. For certain categories, the regulation also uses the peak efficiency index, or PEI.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A rated output specified without indicating the levels of P0 and Pk losses therefore does not allow for a comparison between two transformers. It is necessary to examine the regulatory data corresponding to their category and compare them with the actual operating conditions of the installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Requirements by Processor Category <\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What are the performance requirements for low-power transformers?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">Under the regulation, this category covers transformers whose highest voltage does not exceed 1.1 kV. It includes many <a href=\"https:\/\/www.lecosinus.fr\/en\/transformers\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/transformateurs\/\u201d\" target=\"_self\">low-voltage transformers<\/a>. The currently applicable text does not set a general loss limit for them. However, it requires that no-load losses and load losses be reported in the required technical information. The absence of a maximum threshold therefore does not mean there is no obligation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Performance Requirements for Medium- and High-Power Transformers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For medium-power transformers and certain high-power configurations, the appendices specify maximum losses or a minimum PEI. Level 2 requirements, also known as Tier 2, have been in effect since July 1, 2021. The values vary depending on the rated power, voltage, whether the transformer is dry-type or oil-immersed, and certain specific configurations. It would therefore be misleading to cite a single figure for all transformers.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Regulatory Obligations of Transformer Manufacturers <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before a transformer is placed on the market or put into service, the manufacturer, its authorized representative, or the importer\u2014depending on their role\u2014must determine its category and verify any exclusions. The manufacturer then demonstrates the transformer\u2019s compliance based on the required calculations and tests, retains the technical documentation, and provides the required information on losses and performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The procedure includes conformity assessment, the corresponding declaration, and CE marking in accordance with the applicable framework. The values must be traceable: the term \u201chigh efficiency\u201d does not replace the technical data needed to verify them.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How can you verify compliance before purchasing a transformer?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">The buyer must first specify the power rating, primary and secondary voltages, frequency, load conditions, and installation requirements. The buyer may then request the no-load and loaded losses, the PEI (where applicable), and the compliance documents. Our article on <a href=\"https:\/\/www.lecosinus.fr\/en\/understanding-the-ecodesign-directive-for-electrical-transformers\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/understanding-the-ecodesign-directive-for-electrical-transformers\/\u201d\" target=\"_self\">Ecodesign Directive for transformers<\/a> explains in more detail the difference between low, medium, and high power.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A major renovation requires the same level of vigilance. For a medium- or high-power transformer, the total or partial replacement of the core, combined with the replacement of at least one complete winding, requires a new assessment of the transformer\u2019s compliance. A repair should therefore not automatically be considered a simple maintenance operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A study tailored to actual needs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le Cosinus designs standard and custom transformers. The design process takes into account voltage, power, load, temperature, harmonics, and applicable loss requirements. This data allows for a concrete comparison of the transformers under consideration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">To verify the technical scope of your project and define the expected performance, <a href=\"https:\/\/www.lecosinus.fr\/en\/quote-request\/\" data-type=\"\u201clink\u201d\" data-id=\"\u201chttps:\/\/www.lecosinus.fr\/en\/quote-request\/\u201d\" target=\"_self\">submit your requirements to Le Cosinus<\/a>. For a contractual agreement or a specific regulatory issue, requirements must be confirmed based on the specifications and the version of the text applicable at the time of the project.<\/p>\n\n\n\t<div class=\"lc-cta-hubspot\" data-no-translation>\n\t\t<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-221849051559\"\n\t\t\tstyle=\"max-width:100%; max-height:100%; width:700px; height:237.890625px\"\n\t\t\tdata-hubspot-wrapper-cta-id=\"221849051559\">\n\t\t\t<a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLJqHZbT6vIi5d4%2B%2F1Vg1DMjk1zXL9PX2KXgGwu1MmSL%2B3yG%2FbPMXKk3tEk1y%2Ba8dNt%2F%2Ft3zKoBwy9RUiYNaw96%2BhiL7o2JUQq%2FnN55ifPq0bMP4%2F7rxCzGmSr4vR3CtnvcPWXFzeOZhE1k54o1lyhUEHKMYczmJ0Ex6vMkoADSpD4Ax4lVD3GWCescf9Q%3D%3D&#038;webInteractiveContentId=221849051559&#038;portalId=48243687\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n\t\t\t\t<img alt=\"Request for a quote Enter your product reference number or specify the features of the product you are looking for\"\n\t\t\t\t\tloading=\"lazy\"\n\t\t\t\t\tsrc=\"https:\/\/no-cache.hubspot.com\/cta\/default\/48243687\/interactive-221849051559.png\"\n\t\t\t\t\tstyle=\"height: 100%; width: 100%; object-fit: fill\"\n\t\t\t\t\tonerror=\"this.style.display='none'\" \/>\n\t\t\t<\/a>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Il n&rsquo;existe pas de rendement obligatoire unique pour tous les transformateurs. Dans l&rsquo;Union europ\u00e9enne, les exigences d\u00e9pendent de la puissance, de la tension, de la technologie et de l&rsquo;usage. Selon la cat\u00e9gorie, il faut d\u00e9clarer les pertes ou respecter des valeurs maximales et un niveau minimal de performance \u00e9nerg\u00e9tique. Quelle r\u00e9glementation encadre le rendement des [&hellip;]<\/p>\n","protected":false},"author":4387,"featured_media":96744,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-96743","post","type-post","status-publish","format-standard","has-post-thumbnail","category-norme"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/users\/4387"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/comments?post=96743"}],"version-history":[{"count":10,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96743\/revisions"}],"predecessor-version":[{"id":96754,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/posts\/96743\/revisions\/96754"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/media\/96744"}],"wp:attachment":[{"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/media?parent=96743"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/categories?post=96743"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lecosinus.fr\/en\/wp-json\/wp\/v2\/tags?post=96743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}