Search

LE COSINUS search tool allows you to search quickly and accurately, to find a product datasheet. For a specific product, please contact us.

If you have the reference of the product, enter it below

Alternatively you can search for a product by criteria

Type of product

Sub-category

Number of Phases

Power/Value

Voltage(s)/Current

Indice IP

Result (31 product(s))

Autotransformers Single-Phase

  • Power/Value
    Reference
    Protection
    Wording
  • 250 VA
    1A251-TN-J544
    IP00
    Autotransformers Single-Phase 250 VA 400V / 230V - IP00
    • 1A251-TN-J544

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        84 x 90 x 90

      • Fixings: X x Y x ∅ (mm)

        64 x (56.8 - 67.4) x 4.7

      • Weight

        2

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 1A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 400 VA
    1A401-TN-M976
    IP00
    Autotransformers Single-Phase 400 VA 400V / 230V - IP00
    • 1A401-TN-M976

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 92 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (65.7 - 75.9) x 5.7

      • Weight

        3.5

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe F

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 2A / DJ C - 2A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 630 VA
    1A631-TN-H014
    IP00
    Autotransformers Single-Phase 630 VA 400V / 230V - IP00
    • 1A631-TN-H014

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        108 x 106 x 108

      • Fixings: X x Y x ∅ (mm)

        84 x (78.7 - 88.9) x 5.7

      • Weight

        5

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 4A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1 KVA
    6A102-TN-W135
    IP00
    Autotransformers Single-Phase 1 KVA 400V / 230V - IP00
    • 6A102-TN-W135

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 108 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (64 - 76) x 7

      • Weight

        6.07

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe B

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 4A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 1.6 KVA
    6A162-TN-H129
    IP00
    Autotransformers Single-Phase 1.6 KVA 400V / 230V - IP00
    • 6A162-TN-H129

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        10

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 6A / DJ C - 8A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    6A202-TN-H785
    IP00
    Autotransformers Single-Phase 2 KVA 400V / 230V - IP00
    • 6A202-TN-H785

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 134 x 146

      • Fixings: X x Y x ∅ (mm)

        122 x (91 - 103) x 7

      • Weight

        10

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2 KVA
    6A202-AB-J949
    IP21
    Autotransformers Single-Phase 2 KVA 400V / 230V - IP21
    • 6A202-AB-J949

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        122 x (300 - 128) x 10

      • Weight

        17

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 8A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2.5 KVA
    6A252-TN-G838
    IP00
    Autotransformers Single-Phase 2.5 KVA 400V / 230V - IP00
    • 6A252-TN-G838

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        14

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 10A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 2.5 KVA
    6A252-AB-R737
    IP21
    Autotransformers Single-Phase 2.5 KVA 400V / 230V - IP21
    • 6A252-AB-R737

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        122 x (300 - 128) x 10

      • Weight

        17

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 3.15 KVA
    6A312-AB-V480
    IP21
    Autotransformers Single-Phase 3.15 KVA 400V / 230V - IP21
    • 6A312-AB-V480

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        150 x (300 - 133) x 10

      • Weight

        22

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 3.15 KVA
    6A312-TN-G992
    IP00
    Autotransformers Single-Phase 3.15 KVA 400V / 230V - IP00
    • 6A312-TN-G992

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        150 x 160 x 145

      • Fixings: X x Y x ∅ (mm)

        122 x (117 - 128) x 7

      • Weight

        14

      • Standard

        IEC 61558-2-13

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 10A / DJ C - 16A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 4 KVA
    6A402-AB-H194
    IP21
    Autotransformers Single-Phase 4 KVA 400V / 230V - IP21
    • 6A402-AB-H194

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        300 x 320 x 275

      • Fixings: X x Y x ∅ (mm)

        150 x (300 - 133) x 10

      • Weight

        23

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 20A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 4 KVA
    6A402-TN-G994
    IP00
    Autotransformers Single-Phase 4 KVA 400V / 230V - IP00
    • 6A402-TN-G994

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 166 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (120 - 133) x 9

      • Weight

        19

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 16A / DJ C - 20A

      • Dielectric Input/Output and active/ground

        / 3000V

  • 5 KVA
    6A502-TN-G913
    IP00
    Autotransformers Single-Phase 5 KVA 400V / 230V - IP00
    • 6A502-TN-G913

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        180 x 166 x 153

      • Fixings: X x Y x ∅ (mm)

        150 x (120 - 133) x 9

      • Weight

        20

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 20A / DJ C - 20A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 5 KVA
    6A502-AB-H876
    IP21
    Autotransformers Single-Phase 5 KVA 400V / 230V - IP21
    • 6A502-AB-H876

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 166) x 10

      • Weight

        36

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 20A / DJ C - 20A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 6.3 KVA
    6A632-AB-H449
    IP21
    Autotransformers Single-Phase 6.3 KVA 400V / 230V - IP21
    • 6A632-AB-H449

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 176) x 10

      • Weight

        41

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 25A / DJ C - 32A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 6.3 KVA
    6A632-TN-G907
    IP00
    Autotransformers Single-Phase 6.3 KVA 400V / 230V - IP00
    • 6A632-TN-G907

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 190 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (106 - 166) x 9

      • Weight

        30

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        No

      • Recommended Electrical Protection Input / Output

        DJ D - 25A / DJ C - 32A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 8 KVA
    6A802-AB-J818
    IP21
    Autotransformers Single-Phase 8 KVA 400V / 230V - IP21
    • 6A802-AB-J818

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        375 x 360 x 385

      • Fixings: X x Y x ∅ (mm)

        200 x (340 - 186) x 10

      • Weight

        44

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 32A / DJ C - 32A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 8 KVA
    6A802-TN-J945
    IP00
    Autotransformers Single-Phase 8 KVA 400V / 230V - IP00
    • 6A802-TN-J945

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 200 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (116 - 176) x 9

      • Weight

        34

      • Standard

        IEC 60076-11

      • Winding material

        Copper

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 32A / DJ C - 32A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 10 KVA
    6A103-TN-G819
    IP00
    Autotransformers Single-Phase 10 KVA 400V / 230V - IP00
    • 6A103-TN-G819

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 40A / DJ C - 40A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 10 KVA
    6A103-AB-G908
    IP21
    Autotransformers Single-Phase 10 KVA 400V / 230V - IP21
    • 6A103-AB-G908

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 40A / DJ C - 40A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 12.5 KVA
    6A123-AB-V902
    IP21
    Autotransformers Single-Phase 12.5 KVA 400V / 230V - IP21
    • 6A123-AB-V902

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 50A / DJ C - 50A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 12.5 KVA
    6A123-TN-V898
    IP00
    Autotransformers Single-Phase 12.5 KVA 400V / 230V - IP00
    • 6A123-TN-V898

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        240 x 235 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (146 - 206) x 9

      • Weight

        38

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 50A / DJ C - 50A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 16 KVA
    6A163-TN-G095
    IP00
    Autotransformers Single-Phase 16 KVA 400V / 230V - IP00
    • 6A163-TN-G095

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 235 x 243

      • Fixings: X x Y x ∅ (mm)

        200 x (146 - 206) x 9

      • Weight

        42

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 60A / DJ C - 80A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 16 KVA
    6A163-AB-H130
    IP21
    Autotransformers Single-Phase 16 KVA 400V / 230V - IP21
    • 6A163-AB-H130

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 60A / DJ C - 80A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 20 KVA
    6A203-AB-V903
    IP21
    Autotransformers Single-Phase 20 KVA 400V / 230V - IP21
    • 6A203-AB-V903

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        505 x 480 x 535

      • Fixings: X x Y x ∅ (mm)

        180 x (450 - 200) x 10

      • Weight

        46.5

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 63A / DJ C - 100A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 20 KVA
    6A203-TN-V899
    IP00
    Autotransformers Single-Phase 20 KVA 400V / 230V - IP00
    • 6A203-TN-V899

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        240 x 257 x 362

      • Fixings: X x Y x ∅ (mm)

        180 x (160 - 200) x 10

      • Weight

        46.5

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 63A / DJ C - 100A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 25 KVA
    6A253-AB-G190
    IP21
    Autotransformers Single-Phase 25 KVA 400V / 230V - IP21
    • 6A253-AB-G190

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60Hz

      • Dimensions (L x l x H)

        240 x 257 x 362

      • Fixings: X x Y x ∅ (mm)

        180 x (160 - 200) x 10

      • Weight

        53.41

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 80A / DJ C - 125A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

      • Electrostatic Screen

        Yes

  • 25 KVA
    6A253-TN-V900
    IP00
    Autotransformers Single-Phase 25 KVA 400V / 230V - IP00
    • 6A253-TN-V900

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Dimensions (L x l x H)

        240 x 257 x 362

      • Fixings: X x Y x ∅ (mm)

        180 x (160 - 200) x 10

      • Weight

        46.5

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 100A / DJ C - 110A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 31.5 KVA
    6A313-AB-V904
    IP21
    Autotransformers Single-Phase 31.5 KVA 400V / 230V - IP21
    • 6A313-AB-V904

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 125A / DJ C - 160A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

  • 31.5 KVA
    6A313-TN-V901
    IP00
    Autotransformers Single-Phase 31.5 KVA 400V / 230V - IP00
    • 6A313-TN-V901

      *Dimensions are expressed in millimeters, mass in kilograms and reserves represent the ventilation space to be kept around the product for good heat dissipation. The drawing is not contractual.

      • Use frequency

        50-60 Hz

      • Standard

        IEC 60076-11

      • Winding material

        Aluminium

      • RoHS compliant

        Yes

      • Temperature rise class

        Classe H

      • Eyebolts

        Yes

      • Recommended Electrical Protection Input / Output

        DJ D - 125A / DJ C - 160A

      • Dielectric Input/Output and active/ground

        / 3000V

      • Insulation class

        I

      • Cooling

        Air Naturel

Contact us for any technical information on special products Obtaining a quotation for special products